PW污水泵性能参数:
流量:36-180m3/h;
扬程:8.5-48.5m;
电机功率:4-30KW;
转速:960-2950r/min;
口径:φ65-φ100;
介质温度:≤100℃。
型号 | 流量Q | 扬程 H (m) |
转速 n (r/min) |
功率N(kw) | 效率 η % |
汽蚀余量 (NPSH)r (m) |
吸上真空 HS(m) |
||
---|---|---|---|---|---|---|---|---|---|
(m3/h) | (l/s) | 轴功率 | 电动机功率 | ||||||
50PWF-65 | 10 | 2.75 | 18 | 1440 | 2.35 | 4 | 20.5 | 5 | 6 |
14.5 | 4 | 16 | 2.47 | 25.5 | |||||
19 | 5.25 | 14.5 | 2.58 | 29 | |||||
80PWF-100 | 42 | 11.7 | 14 | 3.5 | 5.5 | 45.5 | 4.5 | ||
56 | 15.5 | 13.5 | 4.1 | 50 | |||||
72 | 20 | 12.5 | 4.5 | 54.5 | |||||
100PWF-125 | 80 | 22.2 | 14 | 5.5 | 7.5 | 55 | 4 | ||
100 | 27.8 | 2.5 | 5.7 | 60 | |||||
125 | 34.7 | 10 | 5.44 | 62.5 | |||||
50PW-65 | 14.5 | 4 | 16 | 1440 | 2.47 | 4 | 25.5 | 5 | 6 |
25 | 6.94 | 32 | 2900 | 3.35 | 4 | 63 | 2.0 | 6 | |
80PW-100 | 56 | 15.5 | 13.5 | 1440 | 4.1 | 5.5 | 50 | 4.5 | 6 |
90 | 25 | 26 | 2900 | 7.0 | 11 | 75 | 3.5 | 6 | |
100PW-125 | 100 | 27.8 | 12.5 | 1440 | 5.7 | 7.5 | 60 | 4 | 6 |
21/2PW | 60 | 16.6 | 9.5 | 1440 | 2.5 | 4 | 62 | 7.2 | |
90 | 25 | 26 | 2920 | 11 | 15 | 58 | 5 | ||
90 | 25 | 43 | 2940 | 17 | 22 | 62 | 5.5 | ||
4PW | 100 | 27.8 | 11 | 960 | 4.7 | 7.5 | 64 | 6.5 | |
160 | 44.4 | 25.5 | 1460 | 18 | 30 | 62 | 7.5 |
型号 |
F(mm) |
T(mm) |
底阀内径 |
备注 |
21/2PW |
2 |
0.15~0.22 |
Φ150 |
|
4PW |
2 |
0.175~0.255 |
Φ200 |
|
PW污水泵故障和排除:
故障现象 | 原因分析 | 排除方法 |
---|---|---|
泵不出水 | 1、进水管路漏气2、吸程太高3、管路阻力太大或堵死 | 1、杜绝漏气2、降低泵安装位置3、清理管路 |
流量不足 | l、进水管径太小2、叶轮流道堵塞3、扬程过高4、转速太低5、水泵反转 | 1、调换进水管 2、清洗叶轮3、开大出水阀4、恢复额定转速5、改变电线接线 |
扬程过低 | 1、流量过大2、转速太低3、轴封损坏 | 1、关小出水阀2、恢复额定转速3、更换轴封 |
功率过大,电机过热 | l、流量太大2、泵内流道堵塞卡住叶轮 3、机泵轴线同轴度超差太大 |
l、关小出水阀 2、消除堵塞物 3、调正机泵中心 |
轴承过热 | 1、轴承腔内润滑脂过多或不足2、泵轴弯曲3、机泵轴线同轴度超差太大 | 1、检查后增减2、校直或更换3、调正机泵中心 |